Description:
Furnace Control Control - replacement for Carrier CES0110074-00/01 control boards
Specifications:
Electrical:
- Line Voltage Range: 98-132 VAC @ 60Hz
- Line Voltage Range: 98-132 VAC @ 60Hz
- Cool Blower: 20A, 2 HP, 240 VAC
- Heat: 10A, 240 VAC
- Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
Timing:
- Inducer Pre-Purge Time: 1 second
- Heat Blower On Delay: 45 seconds
- Heat Blower Off Delays: 120 or 180 second
- Cool Blower On Delay: 1 second
- Cool Blower Off Delay: 1 second
Weight/Dimensions:
- Weight: 0
ICM2804
- Low cost form, fit and functional replacement for Carrier: CES0110074-01
- Hot Surface Ignition (HSI) control board
- Microprocessor-based
- Controls vent motor and blower control
- Monitors limit switch, pressure switch and gas valve
- 100% lockout safety feature
- Compatible with LP or Natural Gas
- Status LED for fault codes to aid in troubleshooting
Click on the link(s) below to open the desired PDF file. All files and the information contained within are subject to change. Please report any broken links to info@icmcontrols.com.
Click the stars to rate the product
Carrier: CES0110074-00, CES0110074-01