Description:
HSI Gas Ignition Control - replacement for popular models, including Honeywell S8910U-1000
Specifications:
Input Voltage: 120 & 24 VAC, 60Hz
- HSI: 120V, 5A max
- HSI: 120V, 5A max
- Valve: 24V, 2A max
- Total: 24V Load = 0.4 + valve load
Pre-purge Time: 32 seconds
Trial Time: 4 or 7 sec (switch selectable)
Ignition Trials to Lockout: 1 or 3 (switch selectable)
Flame Sense: Single rod or dual rod
Gas Type: Natural or LP
Weight/Dimensions:
- Weight: 0.4
- Height: 1.625
- Width: 5.375
- Length: 4
ICM283
- Low cost replacement HSI control for Honeywell, Robertshaw and White Rodgers
- Single/Dual rod sensing capabilities
- For gas fired furnaces, boilers and other heating appliances
- Switch selectable lockout times, ignition trials
- Works with both Natural and LP systems
- Diagnostic LED to aid in troubleshooting
Click on the link(s) below to open the desired PDF file. All files and the information contained within are subject to change. Please report any broken links to info@icmcontrols.com.