ICM283

    00000


Description:


HSI Gas Ignition Control - replacement for popular models, including Honeywell S8910U-1000

Specifications:

    Input Voltage: 120 & 24 VAC, 60Hz
    - HSI: 120V, 5A max
    - Valve: 24V, 2A max
    - Total: 24V Load = 0.4 + valve load
    Pre-purge Time: 32 seconds
    Trial Time: 4 or 7 sec (switch selectable)
    Ignition Trials to Lockout: 1 or 3 (switch selectable)
    Flame Sense: Single rod or dual rod
    Gas Type: Natural or LP

Weight/Dimensions:

  • Weight: 0.4
  • Height: 1.625
  • Width: 5.375
  • Length: 4
ICM283

  • Low cost replacement HSI control for Honeywell, Robertshaw and White Rodgers
  • Single/Dual rod sensing capabilities
  • For gas fired furnaces, boilers and other heating appliances
  • Switch selectable lockout times, ignition trials
  • Works with both Natural and LP systems
  • Diagnostic LED to aid in troubleshooting