ICM286

    12345


Description:


Furnace Control Board - replacement for Goodman PCBBF112S, B1809926S, 0130F00005S control boards

Specifications:

    TIMING
    Inducer Pre-Purge Time: 15 seconds
    Heat Blower On Delay: 30 seconds
    Heat Blower Off Delays: 90/120/150/180 seconds
    Cool Blower On Delay: 5 seconds
    Cool Blower Off Delay: 45 seconds
    Ignitor ON: 7 seconds
    Inducer Post Purge: 15 seconds
    Trails for Ignition: 3 (Before soft lockout)
    Auto Reset: 60 minutes

    ELECTRICAL
    Voltage Range: Line (98-132 VAC) @ 60Hz
    Cool Blower: 30A, 2 HP, 240 VAC
    Heat: 20A, 240 VAC
    Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
    Ignitor: 10A FLA @ 120 VAC
    Humidifier: 5 amps @ 120 VAC
    Electric Air Cleaner: 5 amps @ 120 VAC

Weight/Dimensions:

  • Weight: 0.5
  • Height: 1
  • Width: 6
  • Length: 4.5
ICM286

    The ICM286 Furnace Control Board is a form, fit and functional replacement for Goodman's popular PCBBF112S or B1809926S control board. It features micro-processor based precision with a status LED for testing and easy troubleshooting.

    Features:
  • Controls the gas valve, inducer draft motor, circulating blower and hot surface ignitor
  • Monitors system pressure and limit switches
  • Microprocessor based precision
  • Twinning compatible with another ICM286 Control Board
  • Diagnostic LEDs aid in testing and troubleshooting

Click on the link(s) below to open the desired PDF file. All files and the information contained within are subject to change. Please report any broken links to info@icmcontrols.com.

Click the stars to rate the product
This Is a CAPTCHA Image
Enter the text of the image above

12345 5.0

Posted by: Mr. Goodman Knows

Buy this board to solve your failing boards. The goodman board cube relays are ONLY rated for 22 Volts thats why the board fails! These relays are rated for the 24Volts. Put and ICM board in once and get the service life out of the board instead of a board that has the WRONG 22VOLT cube relay on it that comes from goodman. Ive been putting these in and have not had one fail yet! Goodman board go out left and right these will hold up. if you know hvac all hvac systems use 24Volts why in the world would goodman use a 22 volt relay that sees 24V? Now you know why they burn up you know the PCCBBF boards!!!!!

What's great about it:
they dont fail
What's not so great:
whats not so great about it?
Goodman: PCBBF112S
Goodman: B1809926S