ICM2810

    00000


Description:


Furnace ignition control board replacement for Goodman PCBBF136 and PCBBF140

Specifications:

  • Pre-purge Time: 15 seconds
  • Igniter Warm Up Time: 18 seconds
  • Post-Purge Time: 15 seconds
  • Total Trials for Ignition: 3 (auto rest after 1 hour)
  • Heat Blower On: 30 seconds
  • Heat Blower Off: Selectable 90/120/150/180 seconds
  • Fan (Heat) On/Off Delay: 1 second
  • Cool On: 5 seconds
  • Cool Off: 45 seconds

Weight/Dimensions:

  • Weight: 0.5
  • Height: 1
  • Width: 6
  • Length: 4.5
ICM2810

  • Low cost, Goodman replacement board
  • Microprocessor-based precision
  • Controls inducer and blower fan motors, hot surface igniter, and gas valve
  • Monitors timing, trial for ignition, flame sensing, pressure switches, limit switches
  • Designed for 100% gas shutoff in case of ignition failure
  • Reverse polarity protection
  • Compatible with 24 VAC standard thermostat
  • Twinning compatible with another ICM2810 control board
  • Compatible with LP or natural gas
  • Provides diagnostic LED to aid in testing/troubleshooting

Click on the link(s) below to open the desired PDF file. All files and the information contained within are subject to change. Please report any broken links to info@icmcontrols.com.