Carrier OEM Replacement Control
The ICM291 control is low-cost form, fit and functional replacement board for Carrier: LH33WP003A circuit boards. It controls inducer fan motor, blower fan and monitors limit switches. The ICM291 has incorporated LED diagnostics to assist in troubleshooting. Fault code information can be found in the application guide. Please refer to the application guide with the furnace installation manual for future reference.
Input:
  • Control Voltage: 24 VAC (18-30 VAC), 60 Hz
  • Line Voltage: 208/230 VAC, 60 Hz
Timing:
  • Pre-Purge: 45 seconds
  • Trial for Ignition: 5+2 seconds
  • Retry Period: Every 20 seconds for 15 minutes
  • Lockout: Manual reset
  • Post-Purge: 45 seconds
LED Indicators:
  • Red LED:
    • Steady ON – Normal operation
    • Flashing – fault codes
Flashing-fault codes Inputs:
  • Power: RT and C
  • Thermostat Interface: R,W, and G
  • Safety Switches: RS, LS, and CS
  • Combustion Motor Hall Effect Sensor
Flame Sensing Outputs:
  • Spark – Gas Valve: GV
  • Combustion Motor: CM
  • Blower Motor: BM
  • Indoor Fan Motor: IFO
Weight/Dimensions
  • Weight: 0.5
  • Height: 1.875″
  • Width: 7″
  • Length: 5″