Multi-Functional Timer
Defrost Controls
Time Delay Relays

ICM550-ENC

Share:
Multi-Functional Timer
Defrost Controls
Time Delay Relays

ICM550-ENC

Weatherproof Enclosed Multi-Functional Timer

When Mode B is selected and the unit is in the timed cycle (clock dip switches in the on position), the load will be turned on with the backup source. At the end of the timed cycle, the unit will return to normal operation until the next preset interval occurs.

If Mode A is selected, the load is off during the timed cycle and the backup source will be on. At the end of the timed cycle, the unit will return to normal operation until the next preset interval occurs.

Input:
  • Nominal Voltage Range: 120-240VAC
  • Frequency: 60 Hz
Output:
  • Type: Relay

Environment:

  • Operating temperature: -40 to +131°F
  • Operating humidity: 0-95%, non-condensing

Mechanical:

  • Construction: Open board (plastic bracket mounted). The ICM550-ENC comes packaged in a NEMA Type 4X rated weatherproof enclosure
  • Mounting: Vertical or horizontal orientation

Contact Ratings:

  • Compressor: [2]&[4]: 30A R, 1HP @ 120 VAC, 2HP @ 240 VAC
  • Electric heat: [1]&[3]: 40A R, 1HP @ 120 VAC, 2HP @ 240 VAC
  • Fan: [1]&[F]: 30A R, 1HP @ 120 VAC, 2HP @ 240 VAC
Timing:
  • Minimum cycle time: 15 min
  • Maximum cycle time: 23 hr 45 min
  • Terminate cycle: Cycle can be terminated by shorting “X to N”
Status LED:
  • Cycle mode: (Red LED)
  • Normal mode: (Green LED)
Weight/Dimensions
  • Length: 8.75”
  • Width: 6.50”
  • Height: 2.75”
Sell Sheet
Download
Application/Install Guide
Download

Intermatic / Grasslin: 010-0011B, DT040, DT140, DTAV40, DTAV40M, DT-B, DTMV, DTSX

Paragon: 8041, 8045, 8047, 8141, 8143, 8145, 8245, 8247

Precision: 6041, 6045, 6047, 6141, 06145