ICM (Obsolete/Legacy Products)

ICM286

Share:
ICM (Obsolete/Legacy Products)

ICM286

Goodman OEM Replacement Control
The ICM286 Furnace Control Board is a form, fit and functional replacement for Goodman's popular PCBBF112(S) or B1809926(S) control board. It features micro-processor-based precision with a status LED for testing and easy troubleshooting.
  • Controls the gas valve, inducer draft motor, circulating blower and hot surface ignitor
  • Monitors system pressure and limit switches
  • Microprocessor based precision
  • Twinning compatible with another ICM286 Control Board
  • Diagnostic LEDs aid in testing and troubleshooting
Timing:
  • Inducer Pre-Purge Time: 15 seconds
  • Heat Blower On Delay: 30 seconds
  • Heat Blower Off Delays: 90/120/150/180 seconds
  • Cool Blower On Delay: 5 seconds
  • Cool Blower Off Delay: 45 seconds
  • Ignitor ON: 7 seconds
  • Inducer Post Purge: 15 seconds
  • Trails for Ignition: 3 (Before soft lockout)
  • Auto Reset: 60 minutes

Electrical
  • Voltage Range: Line (98-132 VAC) @ 60Hz
  • Cool Blower: 30A, 2 HP, 240 VAC
  • Heat: 20A, 240 VAC
  • Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
  • Ignitor: 10A FLA @ 120 VAC
  • Humidifier: 5 amps @ 120 VAC
  • Electric Air Cleaner: 5 amps @ 120 VAC
Weight/Dimensions
  • Weight: 0.5 lb.
  • Height: 1″
  • Width: 6″
  • Length: 4.5″
Sell Sheet
Download
Install Guide
Download

Goodman: PCBBF112, PCBBF112S, B1809926, B1809926S, 0130F00005, 0130F00005S

Recommended Alternative: The ICM2811 supersedes the ICM286